Brand Name : BonninTech
Model Number : Gentier48E, Gentier96E
Certification : ISO
Place of Origin : China
MOQ : 1 set
Price : USD8000-25800/set
Payment Terms : L/C, T/T, Western Union, MoneyGram
Supply Ability : 500 set/year
Delivery Time : 5-8 working days
Packaging Details : Standard export wooden box
Equipment : Real Time PCR Machine
Sample capacity(wells) : 48/96
Reaction Volume : 0-100 μL
Gentier96E Real Time PCR Machine Price
Gentier 96E | Gentier 96S | Gentier 96R | Gentier 96C | |
Thermal Block | ||||
Sample capacity(wells) | 96 | |||
Reaction Volume | 0-100 μL | |||
Consumables | 0.2ml 96-well Plates(unskirt); 0.2ml 8-strip tubes ,0.2ml PCR single tube(Optical flat cap,clear,frosted,white tube) | |||
Temperature range | 0°C-100°C | |||
Heating/cooling method | Peltier | |||
Max heating rate | 6.1°C/sec | |||
Average heating rate | 4.5°C/sec | |||
Max cooling rate | 5.0°C/sec | |||
Average cooling rate | 2.8°C/sec | |||
Temperature accuracy | ±0.1℃ | |||
Temperature uniformity | ±0.1℃ | |||
Gradient Range | 1°C-40°C | N/A | 1°C-40°C | N/A |
Gradient block | 12 row | 12 row | ||
Special temperature portocol | Gradient PCR,Long PCR,Touch Down PCR | Long PCR,Touch Down PCR | Gradient PCR,Long PCR,Touch Down PCR | Long PCR,Touch Down PCR |
Heat Lid | ||||
Temperature range | Room Temperature–110°C | |||
Optical System | ||||
Excitation Source | 6 LEDs | 4LEDs | ||
Detector | Photodiode | |||
Detection Position | Excitation and scan at top | |||
Detection method | 6 channels scanning at the same time, no edge effect. | |||
Detection time | 7 seconds for 96 wells for all channels | |||
Range of excitation/ emission wavelengths (nm) | 1 465 /510 (FAM,SYBR Green I,SYTO9,EvaGreen,LC Green) 2 527/ 563 (HEX,VIC,TET,JOE) 3 580 /616 (ROX,Texas Red) 4 632/ 664( Cy5) 5 680 /730 (Alexa Fluor680) 6 465 /616 (FRET) | 1 465 /510 (FAM,SYBR Green I,SYTO9,EvaGreen,LC Green) 2 527/ 563 (HEX,VIC,TET,JOE) 3 580 /616 (ROX,Texas Red) 4 632/ 664( Cy5) | ||
Probe | Taqman Probe,Molecular beacons probe,Scorpion probe ,FRET | Taqman Probe,Molecular beacons probe,Scorpion probe | ||
Multiplexing | Up to 6 targets | Up to 4 targets | ||
Fluorescence Linearity | r≥0.990 | |||
Fluorescence Dynamic Range | Adjustable | |||
Performance | ||||
Sample Linearity | /r/≥0.999 | |||
Sample repeatability | Ct value CV≤0.5% | |||
Sample Dynamic Range | 1-1010 copies | |||
Software Funtions | ||||
Data Analysis modes | Qualitative analysis,Absolute quantification, Relative
quantification,Genotyping analysis,Endpoint analysis, Melt curve analysis, High Resolution Melting | |||
Control modes | 1.10.4' touch screen 2. PC direct control 3. WLAN control(One PC can control max 10 units, and device can be controled by any PC in the WLAN) | |||
Sample Drawer | Touch sreen commend | |||
Data Stroage | Upload and download through USB disk,1000 results can be stored in machine | |||
Power failure protection | Automaticly start running experiments after power supply, no need wait PC software | |||
Customize Report | Templetes reserved ,report can customized | |||
Administration Management | Administrator can set funtions limts for users | |||
Transport Locker | Automaticly detect transport locker | |||
Fault Management | Fault report and analysis, solution instruction | |||
LIS connection | CSV,Excel,TXT format data output,open port for LIS connection | |||
Others | ||||
PC operating system | Win 7, Win 10 | |||
Communication Port | 1 ethernet and 3 USB | |||
Footprint(WxDxH) | 355mm X 480mm X 485mm | |||
Weight | 30kg | |||
Power usage | AC 100 to 125 V / 200 to 240 V (50/60 Hz). | |||
power consumption | 900VA | |||
Work environment | Tempereture:10°C~30°C Humidity:20%~85% |
![]() |